KONE NanoSpace™
Owners Manual
80 (196) OM-01.03.086
(B) 2016-01-11
© 2014 KONE Corporation
All rights reserved.
13 Make a landing call. The elevator must not move.
14 Disable the landing calls.
LCEUI switch 261.
15 Disable the door opening.
LCEUI switch 263.
16 Switch on the Recall Drive Feature
(RDF).
POS 270.
17 Drive downwards on RDF until the
elev
ator car stops.
The pit safety device limit
switch located on the car roof
should stop the
elevator car
before the pit safety device
activates the safety gear
mechanically.
18 Try to drive downwards on RDF. The elevator must NOT move.
19 Make notes of the test. After completing all tests, record the test
date
and all results in the elevator’s log
book at once.