KONE NanoSpace™
Owners Manual
93 (196) OM-01.03.086
(B) 2016-01-11
© 2014 KONE Corporation
All rights reserved.
14
Release the pit stop switch.
15 Close the landing doors. Check that the landing door
is mechanically locked.
16 Go to the Maintenance Access Panel
(MAP).
17 Switch on the Recall Drive Feature
(RDF).
POS 270.
18 Reset the Shaft Access Monitor (SAM),
if applicab
le.
Related information: APPENDIX B.
Resetting the safety devices.
19 Reset the pit safety device. Related information: APPENDIX B.
Resettin
g the safety devices.
20 Drive downwards on RDF until the car
buffer is fully
compressed and the
elevator car stops.
Monitor the speed LEDs in LCEUI.
21 Drive upwards on RDF to raise the
elev
ator car from the buffer.
NOTE! You need enough space for
moving between the bottom landing and
the pit.
Step Action Note