11 Check the operation of the car roof stop
switch.
1. Open the landing door with
emer
gency opening key.
2. Check that the elevator car is in a
su
itable position.
3. Standing on the landing, press the
stop switc
h.
4. Close the landing doors and check
that it is mechanically locked.
5. Check that the stop switch cuts the
safety circuit. (Make
a landing call.
The elevator must not move.) *
If the elevator has Shaft Access Monitor
(SAM), it must be reset.
Related information: APPENDIX B.
Resetting the safety devices.
Make a car call from the Maintenance
Access Pane
l (MAP). The elevator must
not move. Close and lock the MAP.
12 Check the operation of the inspection
drive switch.
1.
Open the landing door with
emer
gency opening key.
2. Standing on the landing, switch on
the inspec
tion drive.
3. Standing on the landing, release the
stop switc
h.
4. Close the landing doors and check
that it is mechanically locked.
5. Check that the inspection drive
prevents the
normal drive. (Make a
landing call. The elevator must not
move.) *
13 Go to the elevator car roof. 1. Open the landing door with
emergency opening ke
y.
2. Standing on the landing, press the
stop
switch.
3. Go to the elevator car roof.
4. Close the landing doors.
5. Check that the landing door is
mechan
ically locked.
14 Check that the buffers are in good
condition.
Polyuret
hane buffers: check that there
are no cracks or powdering.
Step Action Note