Step4.Rotatethefanassemblybracketdowntowardtherearoftheserver.
000000000000000
000000000000000
000000000000000
000000000000000
000000000000000
000000000000000
Figure243.Fanassemblybracketrotation
Step5.Installthehot-swapfans(see“Replacingahot-swapfan”onpage244).
Step6.Installthesystembattery(see“Replacingthesystembattery”onpage271).
Step7.(Trainedtechnicianonly)Installthemicroprocessorandheatsink(see“Replacingamicroprocessor
andheatsink”onpage290).
Step8.Installthememorymodules(see“Installingamemorymodule”onpage214).
Step9.InstalltheServeRAIDSAS/SATAcontroller(see“ReplacingaServeRAIDSAS/SATAcontroller”on
page231
).
Step10.ReconnectthecablestothesystemboardthatyoudisconnectedinStep13onpage301.
Step11.InstallthePCIriser-cardassembliesandadapters,ifanywereinstalled(see“Replacinganadapter”
onpage226
and“ReplacingaPCIriser-cardassembly”onpage221).
Step12.Installtheairbaffle(see“Replacingtheairbaffle”onpage192).
Step13.Installthecover(see“Replacingthecover”onpage190).
Step14.Pushthepowersuppliesbackintotheserver.
Step15.Slidetheserverintotherack.
Step16.Reconnectthepowercordsandanycablesthatyouremoved.
Step17.Turnontheperipheraldevicesandtheserver.
Step18.StarttheSetuputilityandresettheconfiguration.
•Setthesystemdateandtime.
•Setthepower-onpassword.
•Reconfiguretheserver.
See“UsingtheSetuputility”onpage97
formoredetails.
Step19.EitherupdatetheserverwiththelatestRAIDfirmwareorrestorethepre-existingfirmwarefroma
disketteorCDimage.
Step20.UpdatetheUUID(see“UpdatingtheUniversalUniqueIdentifier(UUID)”onpage110).
Step21.UpdatetheDMI/SMBIOS(see“UpdatingtheDMI/SMBIOSdata”onpage112).
Step22.ReactivateanyFeaturesonDemandfeatures.
Chapter6.Removingandreplacingcomponents307