Control terminals
With function "Safe torque off" active
5.6
5.6.3

5.6−4
EDSVF9383V EN 7.1−04/2012
5.6.3 With function "Safe torque off" active
ƒ The installation and commissioning of the Safe torque off" function
must be carried out by skilled personnel only.
ƒ All safety−relevant cables (e.g. control cable for the safety relay,
feedback contact) outside the control cabinet must be protected, for
instance by a cable duct. Short circuits between the single cables must
be ruled out!
Æ’ Wiring of the safety relay K
SR
with insulated wire end ferrules or rigid
cables is absolutely vital.
Æ’ The electrical reference point for the coil of the safety relay K
SR
must be
connected with the protective conductor system (DIN EN 60204−1
paragraph 9.4.3). Only this measure guarantees that the operation is
protected against earth faults.
 Tip!
A complete description can be found in the chapter "Safe torque
off".
Safety instructions for the
installation of the "Safe
torque off" function

Table of Contents

Other manuals for Lenze EVS9321-Ex

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze EVS9321-Ex and is the answer not in the manual?

Lenze EVS9321-Ex Specifications

General IconGeneral
BrandLenze
ModelEVS9321-Ex
CategoryController
LanguageEnglish

Related product manuals