Configuration
Function blocks
Master frequency ramp−function generator (DFRFG)
8
8.2
8.2.4
8.2−14
EDSVF9383V EN 7.1−04/2012
IMPORTANTPossible settingsCode
SelectionLenzeNameNo.
C0758
CFG: IN 1000 FIXEDPHI−0 Selection list 4 Configuration of input signal,
function block DFRFG1
l Speed/phase setpoint signal
8.2−13
C0759
CFG: QSP 1000 FIXED0 Selection list 2 Configuration of digital input
signal, function block DFRFG1
l HIGH = quick stop active
C0760
CFG: STOP 1000 FIXED0 Selection list 2 Configuration of input signal,
function block DFRFG1
l HIGH = Status of the profile
generator is maintained,
setpoint is saved
C0761
CFG: RESET 1000 FIXED0 Selection list 2 Configuration of input signal,
function block DFRFG1
l HIGH = resetting the
integrators
C0764 0 1
Function block DFRFG1
l Display of the signals linked in
C0759, C0760 and C0761
1 DIS: QSP
2 DIS: STOP
3 DIS: RESET
C0765 DIS: IN −32767 {1 rpm} 32767 Function block DFRFG1
l Display of the signal linked in
C0758

Table of Contents

Other manuals for Lenze EVS9321-Ex

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze EVS9321-Ex and is the answer not in the manual?

Lenze EVS9321-Ex Specifications

General IconGeneral
BrandLenze
ModelEVS9321-Ex
CategoryController
LanguageEnglish

Related product manuals