Starting up the device – webConfig tool
Leuze electronic GmbH + Co. KG BPS 348i 99
1 Switch-on signal
2 Switch-off signal
3 Output
4 Start-up delay
5 Switch-on time
Fig.9.5: Start-up delay>0 and switch-on time>0
• Debounce time
Parameter for setting the software debounce time for the switching input. The definition of a debounce
time extends the signal transition time accordingly.
If this parameter has the value 0, no debouncing takes place. Otherwise, the set value corresponds to
the time (in ms) that the input signal must be present and stable.
• Switch-off delay
This parameter specifies the duration of the switch-off delay (in ms).
Configuration of the bar code tape selection and tape value correction (MEASUREMENT DATA tab,
Bar code tape)
• Bar code tape with 30mm grid (BCBG30…) or 40mm grid (BCBG40…) *
• Tape value correction **
Configuration of position detection (DATA PROCESSING tab, Position > Detection)
• Integration depth *
• Scaling free resolution *
• Preset *
• Offset *
• Error handling procedures *
Configuration of position monitoring (DATA PROCESSING tab, Position > Monitoring)
• Position limit value1/2 *
Configuration of speed detection (DATA PROCESSING tab, Speed > Detection)
• Speed measurement averaging *
• Scaling free resolution *
• Error handling procedures *