4-124 Service Manual
7526
Go Back
Previous
Next
Low-voltage power supply (LVPS) removal
See “Low-voltage power supply” on page 7-7 for the part number.
1. Remove the right cover. See “Right cover removal” on page 4-41.
2. Remove the rear frame cover. See “Rear frame cover removal” on page 4-40.
3. Disconnect the connector at JLVPS1 connector (A) and at JLVPS2 (B) on the system board.
4. Remove the cable from the cable restraints (C).
c. Remove the five LVPS mounting screws (D).
d. Press the latch and pull back to disconnect the fuser AC cable from the LVPS (E).
e. Press the latch and pull back to disconnect the power AC cable from the LVPS (F).