Waste toner HV contact assembly removal
See “Waste toner HV contact assembly” on page 7-11 for the part number.
1. Disconnect the transfer module cable (A).
2. Press the two tabs (B) to release the front access door cover assembly.
3. Press the two tabs (C) on either side of the transfer module, and lift out the transfer module.
Note: Leave the photoconductor units on the transport belt when removing.
Warning:To avoid damaging the photoconductor drum, hold the photoconductor units by their handle and
place the photoconductor units on a clean surface. Never expose the photoconductor units to light for a
prolonged period of time.
4. Remove the left cover. See “Left cover removal”.
B AC