Selects the self drive in the 2
nd
switching of Frq2 among the followings
Keypad digital frequency mode1
Keypad digital frequency mode2
V1 terminal setting1: -10 ~ +10V
V1 terminal setting2: 0 ~ +10V
V1 terminal setting1 + I terminal
V1 terminal setting2 + I terminal
Setting via RS-485 communication
Up-Down (Digital Volume) run
Set to FieldBus communication
The following is example for switching of drv1 and drv2.
Multi-function input
terminal P8 input terminal
The following figure is drawn when setting is like the above and command frequency is 30 [Hz],
F4 [stop method]=0
FX
Output Freq.
1 2
30.00
Communication FX
P8 : 2nd Change
3 4 5
① Accelerate for accel time up to setting frequency by Drive 1 mode, FX signal.
② Drive continuously under FX is ON because DRV2 is 1 when P8 terminal input is ON and
change into 2
nd
.
③ Stop gradually as stop command because DRV is communication drive when P8 terminal
input is OFF and change into 1st.
④ Accelerate up to setting frequency for Drive 1 mode, FX signal is ON.
⑤ Stop gradually under FX is OFF because DRV2 is 1 when P8 terminal input is ON and
change into 2
nd
.
If you press ON while multi-function input terminal (P1 ~ P8) is set to 2
nd
Source,
frequency command and drive command is changed to Drive mode 2. So you
should check Drive mode 2 before input multi-function terminal.
For Service Call 800-848-2504