13-1
CHAPTER 13 - SPECIFICATIONS
13.1 Technical data
Input & output ratings: Single Phase 200V Class
Input & output ratings: Three Phase 200V Class
1) Indicates the maximum applicable motor capacity when using a 4-pole standard motor.
2) Rated capacity is based on 220V for 200V class and 440V for 400V class.
3) Refer to 13-4 when Carrier frequency setting (H39) is above 3kHz.
4) Max frequency setting range is extended to 300Hz when H40 (Control mode select) is set to 3
(Sensorless vector control).
5) Maximum output voltage cannot be higher than the input voltage. It can be programmable below
input voltage.
6) N/C: Natural Convention