EasyManuals Logo

LSIS sv-ig5a User Manual

LSIS sv-ig5a
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #146 background imageLoading...
Page #146 background image
9-12
9.6 Output terminal select at loder communication error
Group
Display
Parameter Name
Setting
Range
Default
Unit
I/O group
I57
[Output terminal select
when communication
error with keypad]
-
0 ~ 3
0
Select relay output or open collector output when keypad-inverter communication fails.
Keypad and inverter CPU communication is made by serial communication, delivering
information. When communication error occurs for a certain time, will be
displayed and error signal can be output to MO or relays.
MFI output relay
MFI output terminal
Bit 1
Bit 0
0
-
-
1
-
2
-
3
0: Not used
1: Signal output to MO
2: Signal output to 3A, 3B contacts
3: Signal output to MO, 3A, 3B
For Service Call 800-848-2504
For Service Call 800-848-2504

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSIS sv-ig5a and is the answer not in the manual?

LSIS sv-ig5a Specifications

General IconGeneral
BrandLSIS
Modelsv-ig5a
CategoryInverter
LanguageEnglish

Related product manuals