9.6 Output terminal select at loder communication error
Group
Display
Parameter Name
Setting
Range
Default
Unit
I/O group
I57
[Output terminal select
when communication
error with keypad]
-
0 ~ 3
0
Select relay output or open collector output when keypad-inverter communication fails.
Keypad and inverter CPU communication is made by serial communication, delivering
information. When communication error occurs for a certain time, will be
displayed and error signal can be output to MO or relays.
MFI output relay
MFI output terminal
Bit 1
Bit 0
0
-
-
1
-
2
-
3
0: Not used
1: Signal output to MO
2: Signal output to 3A, 3B contacts
3: Signal output to MO, 3A, 3B