5-25
I79
A44F
[Write
address
register
6]
6
I80
A450
[Write
address
register
7]
7
I81
A451
[Write
address
register
8]
8
182
1)
A452
[Brake
open
current]
0~180
[%]
Sets current level to open the brake.
It is set according to H33s (motor rated
current) size
50.0
O
8-26
183
A453
[Brake
open
delay
time]
0~10
[s]
Sets Brake open delay time.
1.00
X
184
A454
[Brake
open FX
frequenc
y]
0~400
[Hz]
Sets FX frequency to open the brake
1.00
X
185
A455
[Brake
open RX
frequenc
y]
0~400
[Hz]
Sets RX frequency to open the brake
1.00
X
186
A456
[Brake
close
delay
time]
0~19
[s]
Sets delay time to close the brake
1.00
X
187
A457
[Brake
close
frequenc
y
0~400
[Hz]
Sets frequency to close the brake
2.00
X
1):
It is indicated when choosing I54~I55 as a 19 (Brake signal).
For Service Call 800-848-2504
For Service Call 800-848-2504

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSIS sv-ig5a and is the answer not in the manual?

LSIS sv-ig5a Specifications

General IconGeneral
BrandLSIS
Modelsv-ig5a
CategoryInverter
LanguageEnglish

Related product manuals