7-6
Frequency setting via Digital Volume (up-down)
Group
Code
Parameter Name
Setting
Range
Initial
Unit
Drive
group
0.0
[Frequency Command]
-
0 ~400
0.00
Hz
Frq
[Frequency Mode]
8
0 ~ 9
0
Select 7 in Frq code of Drive group.
Related code: I 59, I 60, I 61
Refer to Chapter 13. RS485 communication.
Analog Hold
Group
Code
Parameter Name
Setting
Range
Initial
Unit
Drive
group
Frq
[Frequency Mode]
2 ~ 7
0 ~ 9
0
I/O group
I17
[Multi-function input terminal
P1 define]
-
0 ~25
0
~
~
I24
[Multi-function input
terminal P8 define]
23
7
It is available when Frq code setting is 2 ~ 7.
Select one terminal to use for Analog Hold command among Multi-function input terminal
(P1 ~ P8).
When P8 terminal is selected,
Frequency
P8
Operation
command
Set freq.