Note: Each X.121 address must be unique for each DynaStar box. Therefore, it
is recommended that a naming convention be used so that the address for the
first DRM (node #=1) port 102, the X.121 address will be 3102. (3+1–1) * 1000 +
102 = 3102.
For the second DRM, same port, the address will be 4102.
(3+2–1) * 1000 + 102 = 4102.
The limit for X.121 address is 65555.
11. (Enter to access the terminal through Telnet only) At Telnet command, enter -N
-Q -H FB03
12. Press the left arrow key twice.
Response: Cursor is displayed at Process selections (Y/N).
13. Enter Y.
14. To save to flash, Enter: <ctrl>w
Response: The settings are saved to memory.
15. Press the <Esc> key until the main menu appears.
Response: The main menu is displayed.
16. Enter <ctrl> ].
Response: Telnet>
17. Enter quit.
Response: Connection Closed.
18. Execute Procedure 3.3.
3.7.2 Program the Serial Port of the OS Router for PAD Access
Note: Use the following procedure only for remote terminal access to DRM SAI Port
Devices.
1. At the main menu, enter 3 for configuration.
Response: The Configuration Commands menu is displayed.
2. Enter 6 for Async Services.
Response: The Access Server Commands menu is displayed.
3. Enter 2 for PAD profiles.
Response: The PAD Profiles menu is displayed.
4. At 85(10), enter DRM.
5. At Enter profile number to view/change X.3 parameters, enter 85.
Response: The X.3 Parameter Values menu is displayed.
NETWORK PROCEDURES
Procedure 3.7
235-200-150
January 2003
Page 3.7-4 Issue 3.00