6. Connect the ROP connection to the DB-25 parallel connector on the Netra 20
and Power up the ROP.
7. Connect the DC power to the Netra 20
Continue with step A6.11 “Power Up the Netra 20”
A5.11 Power Up the
Netra
20
Power up the Netra 20, but immediately after the banner (on the MCC this will be a
line of text that begins with "Sun Netra T4") is displayed, return to firmware mode
(the "ok" prompt) by entering a break sequence on the MCC keyboard. For example,
hold down the Control key and press F5.
Note: Note: when you power up the Netra 20, if you do not see the boot sequence
begin on the screen, you must switch to the Sun console side of the terminal by
holding down the Ctrl key and pressing Enter (not Return) on the MCC.
A5.12 Boot
Netra
20 OS from CD-ROM
You will now load the Netra 20 AW from the CD-ROM: "3B21E Emulator and SUN
OS," Netra version, for the current release.
Refer to the DRM User’s Guide, Section 4.5.8, "Format the primary or Secondary Disk
from a Boot CD-ROM (Netra 20).”
Please Note the Following:
1. Begin at step 2. Step 1 indicates to "Stop the AW" which has already been
completed.
2. Format and load the Netra 20 primary disk, that is, you must execute Step 5.
A5.13 Restore the
5ESS
-2000 MHDs
If the Netra t 1120 was stable at Step A5.5.1 then, execute Step A5.13.1 otherwise
execute Step A5.13.2
A5.13.1 Stable System Restore
1. As soon as the EAI page is initialized on the screen, halt the 3B21 emulator
from the Emergency Action Interface (EAI) page by entering the poke 59! and
responding “y” to the verify request. You will have to time your input between
initializations if the system is rolling in initializations.
2. Insert the “5ESS Generic Release” DAT tape created in A6.7, Step 3 into the
Netra 20 Tape Drive.
3. This step will initialize the primary MHD community (MHD 0 and MHD 2) with
the office data and 5ESS Generic from the Netra t 1120 to tape.
Note: Please type carefully and check the input before hitting enter for the
dd commands. The character n as the last character in the Input File tape
device name of the first dd command specifies a non-rewinding tape read. The
second “dd” command will cause the tape to rewind. These commands will each
take up to 20 minutes. Wait until the first command is completed before
entering the second command.
Execute the following commands:
/bin/dd if=/dev/rmt/0hn of=/dev/rdsk/c1t0d0s7 bs=131072
/bin/dd if=/dev/rmt/0h of=/dev/rdsk/c1t0d0s5 bs=131072
APPENDIX 5
5ESS Switch DRM Administrative Workstation
NETRA
t 1120
to
NETRA
20 WITH SOLARIS 8 OS CONVERSION PROCESS
GUIDELINES
235-200-150
May 2003
Page A5-6 Issue 3.00

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent 5ESS DRM and is the answer not in the manual?

Lucent 5ESS DRM Specifications

General IconGeneral
BrandLucent
Model5ESS DRM
CategoryControl Unit
LanguageEnglish