After each command completes, refer to the record count noted in Section A6.7.
Verify that the count of records transferred from the tape with each command in
this step is exactly equal to the count of records transferred to the tape in
Section A6.7. If the counts differ from the counts previously recorded, seek
technical assistance.
XXXX + xxxx records in
YYYY + yyyy records out
4. Remove DAT tape from DAT drive.
5. Insert the “5ESS DRM Network Config Files” DAT tape created in step A6.7,
Step 5, into the Netra 20 Tape Drive.
6. To restore the DRM Network Configuration Files, enter the following command;
/bin/cpio –icvdu < /dev/rmt/0h
7. Remove DAT tape from DAT drive.
8. Login in to the Administration ID by typing "awadmin" at the console login
prompt.
9. From the Administrative Workstation Main Menu, select “Boot the Workstation”.
Answer yes to the confirmation. If you select a task by mistake, answer no to
the confirmation.
Response:
You have chosen to boot the workstation. If the Emulator is running,
it must be halted before continuing. Refer to the Main Menu item of
Halt the Emulator.
Do you want to continue? (yes/no) yes
10. Wait for the boot sequence to complete and then switch back to the MCC view by
holding down the Ctrl key while pressing Enter.
11. Continue with Section A5.14, “Verify the Netra 20”
A5.13.2 Unstable System Restore
If the Netra t 1120 was not stable at step A5.7, then execute this step
This procedure is done in two steps. The first step is to provision the Network
Configuration files and the second step is to recover the 5ESS software and databases.
A5.13.2.1 Configure DRM Network qfe0 Port
Login to the new Netra 20 as awadmin and select the option for Configure DRM
Network qfe0 Port and follow the procedures outlined in Section A5.16
A5.13.2.2 Recover the 5ESS Software
To recover the 5ESS software, load the system following instructions from Section
7.1.3, Load TOP, AM Text, and AM ODD from Multi-Volume Formatted Backup Tapes”
from the DRM User’s Guide
A5.14 Verify the
Netra
20
The following steps are recommended to verify the operation of the new system.
1. Ensure that call processing is operating normally. Perform test calls per local
procedures. If any problems are found, seek technical assistance.
235-200-150
May 2003
APPENDIX 5
5ESS Switch DRM Administrative Workstation
NETRA
t 1120
to
NETRA
20 WITH SOLARIS 8 OS CONVERSION PROCESS
GUIDELINES
Issue 3.00 Page A5-7