EasyManua.ls Logo

Manitowoc GROVE GMK6400

Manitowoc GROVE GMK6400
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance work on the carrier
7.4 Fuel system
16.11.2018
Maintenance manual 3 302 756 en 7 - 31
GMK6400
7.4.3 Changing fuel filter 2
Spare parts
and
tools
Receptacle, about 5 l (1.5 gal); à p. 2 - 4.
Torque wrench for a torque of 25 Nm (18.4 lbf ft).
Prerequisites The truck crane must be level and on outriggers; à Operating manual.
The main boom must be fully raised; à Operating manual.
The engine must not be running and must be secured against unauthor-
ised use; à p. 2 - 3.
Emptying the
fuel
line
Place a receptacle underneath the filter.
Close the valve – lever (1) at right angles to
the line.
Open the drain plug (2) and let the
consumable drain out.
s
M 12
Designation Quantity GROVE part no.
Filter with gasket 1 03319653
O
Risk of environmental damage due to leaking consumables!
Always let consumables drain into suitable receptacles. Wipe up any
consumables that escape.
Store/dispose of consumables and any soaked equipment properly.
Ask about the applicable regulations.

Table of Contents