Maintenance work on the carrier
7.15 Central lubrication system
16.11.2018
Maintenance manual 3 302 756 en 7 - 107
GMK6400
7.15 Central lubrication system
The central lubrication system supplies the steering lever and all the axle
lines.
7.15.1 Checking the filling level
Grease, spare
parts, tools
Filling pump from the tool set.
Prerequisites The parking brake must be engaged.
Checking the
filling level
Check the filling level in the grease
container (1).
The filling level must be near the max.
marking.
If it is below the min. marking, the level is
too low.
If the level is too low
Top up the grease; à p. 7 - 108.
s
W
Lubricating
grease
Designation
to DIN 51502
Specifications
Classification
GROVE part no.
Grease KP - 1K - 50 DIN 51825 03233369