EasyManuals Logo
Home>Manitowoc>Construction Equipment>GROVE GMK6400

Manitowoc GROVE GMK6400 User Manual

Manitowoc GROVE GMK6400
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #154 background imageLoading...
Page #154 background image
Maintenance work on the carrier
7.11 Suspension
7 - 82 3 302 756 en Maintenance manual
GMK6400
16.11.2018
7.11.4 Pressure accumulator – checking the gas pressure
The gas pressure must be checked every 3,000 operating hours, but always
at least every 12 months.
The suspension has integrated, nitrogen-filled
pressure accumulators (1).
The filling pressure at 20 °C (68 °F) is 40 bar
(580 psi).
• Have the filling pressure checked, and if
necessary corrected, by
Manitowoc Crane Care
or an authorised GROVE dealer or an
authorised specialist workshop.
M 12
G
Risk of accidents due to incorrect inspection!
The gas pressure test must be carried out only by an authorised official
inspector of pressure tanks or under his/her supervision or instructions.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK6400 and is the answer not in the manual?

Manitowoc GROVE GMK6400 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK6400
CategoryConstruction Equipment
LanguageEnglish

Related product manuals