Maintenance work on the carrier
7.4 Fuel system
16.11.2018
Maintenance manual 3 302 756 en 7 - 33
GMK6400
Bleeding the
fuel
line
A receptacle is under the end of the hose (2).
Close the drain plug (3).
Open the valve – lever (1) parallel to the line.
Open the valve – lever (5) horizontal.
Operate the pump (4), until the consumable
flowing through the end of the hose no
longer contains any bubbles.
Turn the valve – lever (1) vertical.
Start the engine and check the filter for
leaks.
Remove the receptacle underneath the hose
end (2).
H
If you have used a clean receptacle, you can refill the fuel tank with the
consumable using a filter.
Otherwise dispose of the consumable properly.