EasyManua.ls Logo

Manitowoc GROVE GMK6400

Manitowoc GROVE GMK6400
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance work on the carrier
7.5 Exhaust system with exhaust emission control
7 - 38 3 302 756 en Maintenance manual
GMK6400
16.11.2018
Checks
Check the exhaust pipes (2) from the
engine (1) to the silencer (3) for damage.
The exhaust pipes (2) may not have any
holes or cracks.
Check that the vicinity of the exhaust pipes
is free of loose components that could burn
by coming into contact with the hot exhaust
system.
Check the nozzles (4) for injecting AdBlue for
external damage.
After checking
Start the engine.
Check the Adblue system lamp on the instrument panel; à p. 7 - 36.
Check if exhaust gases are leaking from any damaged places in the
exhaust system.
Switch the engine off.
If you discover any damage
Have any damaged parts of the exhaust system replaced immediately by
Manitowoc Crane Care or an authorised GROVE dealer.
G
Risk of burns when the exhaust system is hot!
During operation, the exhaust system heats up to 400 °C (750 °F). Wear
suitable gloves and wait until the exhaust system has cooled down.
Take
care not to touch any hot parts.

Table of Contents

Related product manuals