Maintenance work on the carrier
7.14 Hydraulic system
7 - 96 3 302 756 en Maintenance manual
GMK6400
16.11.2018
Taking oil samples
The hose end (1) is connected to the
cylinder (3).
The hose end (2) is in the receptacle (4).
Start the engine.
Allow 2 litres (0.5 gal) of oil to flow into the
receptacle.
Switch the engine off and insert the hose
end (2) into the sample container (5).
Start the engine.
Allow 0.3 litres (0.08 gal) of oil to flow into
the sample container.
Switch the engine off.
Put the hose end back into the receptacle.
Seal the sample container.
Connecting
Removing
Disconnect the hose (2) – the gauge port (1) closes.
Close the gauge port with the cap.
Allow the oil to flow out of the hose into the receptacle (3).
Close the hose ends with the caps (4).
Remove the receptacle and properly dispose of the oil.
Attach the cover (1).