Maintenance work on the carrier
7.19 Other maintenance work
7 - 136 3 302 756 en Maintenance manual
GMK6400
16.11.2018
Spraying
Use a spray extension to spray the corrosion
protection agent on the underside of the
carrier.
Clean accidentally sprayed surfaces
immediately with water.
Let the corrosion protection dry for one
hour.
Check that a transparent waxy protective
film has covered the entire surface.
G
Risk of injury to the eyes!
While working with the spray extension you could be hit by the spray jet or
spray droplets. Wear protective goggles, protective clothing and gloves.