Loading...
Maintenance work on the superstructure
8.7 Hydraulic system
16.11.2018
Maintenance manual 3 302 756 en 8 - 59
GMK6400
Establishing
the
operating
condition
After changing the oil filters and topping up the oil, you must re-establish
the operating condition.
Opening the valves
Open the valves – lever (1) parallel with
the
line.
Start the engine.
Carry out all hydraulic functions several times to remove any air in the
system.
Check that none of the oil filters is leaking.
Check the oil level through the sight glass on the hydraulic oil tank.
Top
up oil if necessary; à p. 8 - 58.
S
Risk of damage to the hydraulic pumps!
Open the valve prior to starting the engine.
This prevents damage to the hydraulic pumps.