Run-in regulations
4 - 2 3 302 756 en Maintenance manual
GMK6400
16.11.2018
Operating hours
(oper. hrs.)
Additional maintenance work on the
SUPERSTRUCTURE
during the first 100 Check the hydraulic oil filter every week, and
change it if necessary;
à Cleaning the magnetic rods, p. 8 - 46,
à Changing the hydraulic oil filter, p. 8 - 53.
after 100 Tighten the screws on the slewing bearing;
à Checking the bolts, p. 8 - 23,
à Special torques, p. 10 - 2.
after 100 Hook blocks;
à Lubricating, p. 8 - 91.
after 200 Change the oil for the pump transfer case;
à Changing the oil, p. 8 - 37.
after 200 First oil change on the hoists;
à Changing the oil/checking the oil, p. 8 - 14.
after 1,000 or after
12
months at the latest
Second oil change on the hoists;
à Changing the oil/checking the oil, p. 8 - 14.
after 200 Change the slewing gear oil;
à Changing the oil/checking the oil, p. 8 - 20.