Maintenance overview
5.4 Measures required for monitoring the winches
5 - 26 3 302 756 en Maintenance manual
GMK6400
16.11.2018
5.4.3 Example
A GMK6400 is equipped with a separate operating hours counter for the
hoist and is classified by Manitowoc Crane Group Germany GmbH as
follows:
The used proportion S of theoretical service life is calculated based on the
individual inspection intervals as follows:
1st inspection (1st year)
The truck crane was used for assembly work during the previous year:
Load
spectrum L 1, i.e. Km
1
= 0.125.
The operating hours counter for the main hoist reads 160 h, i.e. T1 = 160 h.
The used proportion S
1
of theoretical service life at the 1st inspection is
thus:
Remaining theoretical service life:
D1 = 3,200 h -160 h = 3,040 h.
The aforementioned values are entered in the table (see table example
p. 5 - 28).
2nd inspection (2nd year)
The truck crane was used for unloading work on docks:
Load spectrum: L 3, i.e. Km
2
= 0.5.
The operating hours counter for the main hoist reads 640 h, i.e. during this
period: 640 hrs. - 160 hrs. = 480 hrs. (160 hrs. were used during the first year)
T2 = 480 hrs.
Power unit group: M 3
Load spectrum: light L 1, Km = 0.125
Theoretical service life: D = 3,200 h
S
i
0.125
0.125
---------------
160 h× 160 h==

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK6400 and is the answer not in the manual?

Manitowoc GROVE GMK6400 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK6400
CategoryConstruction Equipment
LanguageEnglish

Related product manuals