Maintenance work on the carrier
7.3 Engine
16.11.2018
Maintenance manual 3 302 756 en 7 - 23
GMK6400
Have the radiator units (1) and (2) opened up by the repair specialists,
so
that the radiator fins are accessible.
Have the radiator fins (4) cleaned on both sides, using suitable cleaning
agents.
Have the fan impellers (6) cleaned.
Have the cooling baffles (5) cleaned.
Have the hoses and connections checked for damage and leaks.
Have any damaged parts replaced.
After checking/
cleaning
Remove all tools and cleaning equipment.
Check that all the grilles (3) and plates (5) are securely fastened.
Start the engine and wait until the fan impellers (6) rotate.
Check that the fan impellers run freely (6).
Check the respective temperature displays in the driver's cab;
à Operating manual.
Switch the engine off.
Check the radiator and connections for leaks.