Matrox 4Sight technical reference 169
LEDs
■ Power: Power on/off.
■ Diagnostic: Communicates system errors.
■ 100 MBPS: On in 100BaseT mode; off in 10BaseT mode.
■ Activity: Blinks when transmitting/receiving packets.
Environmental specifications
Matrox 4Sight motherboard
■ Ambient operating temperature with 200 lfm of air flow:
10 to 60° C.
■ Ambient operating temperature with no air flow: 10 to 40° C.
■ Storage temperature: -40 to 65° C.
■ Operating altitude: -300 to 3000 meters.
■ Storage altitude: -300 to 12000 meters.
■ Operating humidity: 10 to 90 % (non-condensing).
■ Storage humidity: 5 to 95 % (non-condensing).
■ Vibration, operating: 0.67 gRMS (5 - 500 Hz).
■ Vibration, storage: 36 RMS (5 - 500 Hz).
Matrox 4Sight integrated unit
■ Ambient operating temperature: 10 to 50° C.
■ Storage temperature: -40 to 65° C.
■ Operating altitude: -300 to 3000 meters.
■ Storage altitude: -300 to 12000 meters.
■ Operating humidity: 10 to 90 % (non-condensing).
■ Storage humidity: 5 to 95 % (non-condensing).
■ Vibration, operating: 0.67 gRMS (5 - 500 Hz).
■ Vibration, storage: 36 RMS (5 - 500 Hz).