FOCKE MELER GLUING SOLUTIONS INSTALLATION
3-2
To calculate the space necessary to install the equipment in terms of its
length, you must add at least 280 mm to the measurements indicated in the
table in order to be able to open the distributor’s filter-purger access door.
Electrical Consumption
In order to install a melter equipment os this serie, we should take into
consideration the total consumption of the installation, including the
consumption of the installed hoses and applicators.
Before connecting, make sure that the voltage that is being connected to the
melter is the correct one appearing on the equipment’s characteristics plate.
Connect the machine and check to see if it is well grounded.
Warning: Risk of electrocution. Even when the equipment is turned off,
voltage remains in the intake terminals, which may be dangerous during
internal equipment manipulations.
Install a power switch for disconnecting the melter equipment from the
electrical network. It must be protected against overload and short circuits by
circuit breaker and install appropriate personal protection leads to mass by
differential switch.
Consumption figures, according to melter and output configuration, are
included in the table in the section ‘Electrical power connection’.