FOCKE MELER GLUING SOLUTIONS
4-8
MELTER OPERATION
Temperature adjustment
The melters leave the factory with the following set point temperature values:
• 160 °C for the tank and distributor
• 160 ºC for the hoses and applicators
• °C displayed
• Overheating value: 20°C
• Standby value: 40%
• Delay time: 10 min
• On/off and stanby programming: ON
• Low level detector: ON
The general process for adjusting the temperatures of each components is
described below.
1. Select the component whose value you wish to modify using the left-
right arrow. The tank and the distributor have the same set point value.
The corresponding LED will blink rapidly.
2. Select the desired set point temperature value with the up-down arrow.
Below 40°C the set point value displays ‘OFF’ canceling the heating of
that element.
3. After ten seconds, the LED will stop blinking and the display will show
the tank’s set point temperature value by default, saving the modified
data.
This simple procedure should be repeated for each of the components whose
set point temperature value you wish to modify.