MELTER OPERATION
4-5
MA-5079-ENG MICRON GEAR ADHESIVE MELTER
Alarm displays
The melter equipments tell the user when a malfunction has occurred in
the unit, sending warning messages that may be seen on the control panel
display.
When an alarm appears, the control unit takes a series of steps to protect the
unit. Simply correct that malfunction and the control unit will reactivate the
equipment functions.
Code Source
Actions
Heating Pump Main machine signal
Err 0 tank broken sensor only tank off off off
One pump installed
Err 1 hose1 broken sensor only hose1 off off off
Err 2 applicator1 broken sensor only applicator1 off off off
Err 3 hose2 broken sensor only hose2 off off off
Err 4 applicator2 broken sensor only applicator2 off off off
Err 5 hose3 broken sensor only hose3 off off off
Err 6 applicator3 broken sensor only applicator3 off off off
Err 7 hose4 broken sensor only hose4 off off off
Err 8 applicator4 broken sensor only applicator4 off off off
Err 9 hose5 broken sensor only hose5 off off off
Err 10 applicator5 broken sensor only applicator5 off off off
Err 11 hose6 broken sensor only hose6 off off off
Err 12 applicator6 broken sensor only applicator 6 off off off
Err 13 distributor broken sensor only distributor off off off
Err 100 tank overheating all components off off off
Err 101 hose1 overheating all components off off off
Err 102 applicator1 overheating all components off off off
Err 103 hose2 overheating all components off off off
Err 104 applicator2 overheating all components off off off
Err 105 hose3 overheating all components off off off
Err 106 applicator3 overheating all components off off off
Err 107 hose4 overheating all components off off off
Err 108 applicator4 overheating all components off off off
Err 109 hose5 overheating all components off off off
Err 110 applicator5 overheating all components off off off
Err 111 hose6 overheating all components off off off
Err 112 applicator6 overheating all components off off off
Err 113 distributor overheating all components off off off

Table of Contents