FOCKE MELER GLUING SOLUTIONS
4-6
MELTER OPERATION
Code Source
Actions
Heating Pump Main machine signal
Err 0 tank broken sensor only tank off off off
Two pumps installed
Err 1 distributor1 broken sensor only distributor1 off off off
Err 2 null -
Err 3 distributor2 broken sensor only distributor2 off off off
Err 4 null -
Err 5 hose1 broken sensor only hose1 off off off
Err 6 applicator1 broken sensor only applicator1 off off off
Err 7 hose2 broken sensor only hose2 off off off
Err 8 applicator2 broken sensor only applicator2 off off off
Err 9 hose3 broken sensor only hose3 off off off
Err 10 applicator3 broken sensor only applicator3 off off off
Err 11 hose4 broken sensor only hose4 off off off
Err 12 applicator4 broken sensor only applicator4 off off off
Err 13 null -
Err 100 tank overheating all components off off off
Err 101 distributor1 overheating all components off off off
Err 102 null -
Err 103 distributor2 overheating all components off off off
Err 104 null -
Err 105 hose1 overheating all components off off off
Err 106 applicator1 overheating all components off off off
Err 107 hose2 overheating all components off off off
Err 108 applicator2 overheating all components off off off
Err 109 hose3 overheating all components off off off
Err 110 applicator3 overheating all components off off off
Err 111 hose4 overheating all components off off off
Err 112 applicator4 overheating all components off off off
Err 113 tank2 overheating