MELTER OPERATION
4-15
MA-5079-ENG MICRON GEAR ADHESIVE MELTER
Counter that warns of the need to change the adhesive
agent filter
This function is a partial countdown counter that registers the hours of equi-
pment operation, that is, with service temperature OK activated, from tP1000
hours to tP0000 hours.
When this value is reached, the display shows the ‘FIL tEr’ message, which
warns that the adhesive filter of the equipment must be cleaned and/or repla-
ced.
Press any key to delete the message and the counter will return again to 1000
hours. The equipment will return to the same mode of operation that was
activated before the message appeared.
Use the ‘up’ and ‘down’ keys of this function to modify this value so the filter
cleaning warning adjusts to the specific needs required for melter operation.
Once the value has been selected, press the ‘right’ key to store the new value
and the ‘FIL tEr’ warning will be activated after the new programmed time
elapses.