78
• Faulty right exhaust – CODE 3
(this appears for example when the pressure switch does not work properly)
1. Press ‘Silent’.
2. Check the air speed thresholds in General settings.
3. Press + and – to set the correct air speed (only if there is a motor).
4. Press 'Clear' to cancel the alarm.
5. Contact customer support if the problem cannot be solved.
• Motors thermal overload – CODE 4
1. Press 'Clear' to reset the alarm.
2. Contact customer support if the problem cannot be solved.
• Glass Open – CODE 5
1. Close the front shield.
2. Contact customer support if the problem cannot be solved.
• Air speed out of range – CODE 6
(this appears for example when outside of the in General settings thresholds)
1. Press ‘Silent’.
2. Check the Speed thresholds in the General software settings.
3. Press + and – to set the correct air speed (only if there is a motor).
4. Press 'Clear' to reset the alarm.
5. Contact customer support if the problem cannot be solved.
• Exhaust fault– CODE 7
1. Press 'Clear' to reset the alarm.
2. Contact customer support if the problem cannot be solved.
• Charcoal filter expired – CODE 10
1. Press ‘Silent’.
2. Call customer support to replace the filter.
• HEPA filter expired - CODE 11
1. Press ‘Silent’.
2. Call customer support to replace the filter.
• Internal filters expired - CODE 12
1. Press ‘Silent’.
2. Call customer support to replace the filter.
• Tank left full – CODE 13
1. Wear the dedicated PPE.
2. Lift the unit to the maximum height.
3. Empty the full tank.
4. Contact customer support if the problem cannot be solved.
• Tank right full – CODE 14
1. Wear the dedicated PPE.
2. Lift the unit to the maximum height.
3. Empty the full tank.
4. Contact customer support if the problem cannot be solved.