3 - 4 Operator’s Manual
3 System Preparation
3.3 Power ON/OFF
CAUTION
To ensure safe and effective system operation, you must perform daily
maintenance and checks. If the system begins to function improperly,
immediately stop scanning. If the system continues to function improperly, fully
shut down the system and contact the Mindray Customer Service Department
or a sales representative. If you use the system in a persistent improperly
functioning state, you may harm the patient or damage the equipment.
3.3.1 Check before Powering ON
Check before the system is powered on:
The temperature, relative humidity and atmospheric pressure meet the requirements of the
operating conditions. For details, see “2.4.2 Environmental Conditions”.
There is no condensation.
There is no distortion, damage or dirt on the system and peripheral devices.
If any dirt is found, cleaning shall be performed. For details, see “19 System Maintenance”.
There are no loose screws on the monitor, control panel.
There is no cable damage (e.g., power cord). Maintain secure connections to the system at all
times.
The probes and probe cables are free from damage or stains.
For details of probe cleaning and disinfection, see “17.1.5 Probes Cleaning and Disinfection/
Sterilization”.
No miscellaneous odds and ends are attached or affixed to the control panel.
Ensure that all connections are free from damage and remain clear of foreign object blockages.
There are no obstacles around the system and its air vent.
Probe cleaning and disinfection.
The entire scanning environment and field must be clean.
The locking mechanism of the casters can works normally.
3.3.2 Power the System ON
After the power indicator on the touch panel becomes green, press the power button to power the
system on.
If access control has been set by the system administrator, you can access data in the system only
after logging onto the system.
To Login onto the System
Perform the following procedure:
1. Select the login type (Local or LDAP), and user name in the drop-down list.
2. Enter the password and click [Login].
When the user has logged onto the system, is visible in the bottom-right corner of the
screen.
To Change Users
Perform the following procedure: