Installation
131
Mitel 470 as of R4.1
syd-0585/1.2 – R4.1 – 08.2016
Restrictions
The maximum length of an DSI-AD2 bus is further restricted by:
the maximum power requirements of the connected system phones and their sup-
plementary equipment. In this context the SB-4+ and SB-8 DECT radio units are
also considered as system phones.
the line resistance (depending on the line length and wire diameter)
Tab. 60 Maximum power requirements of the system phones on the DSI bus
System phone
1)
1) Assumptions:
System phones: In hands-free mode, loudspeaker on maximum volume, all LEDs lit
MiVoice 5380: Backlighting with maximum brightness
Expansion key modules: All LEDs lit
Radio units: Active call connection on all channels
Socket
Max. power input
[mW]
MiVoice 5360
2)
2) Although no longer available, the phone is still supported.
DSI-AD2 interface 900
MiVoice 5361 DSI-AD2 interface 1220
3)
MiVoice 5370 DSI-AD2 interface 1220
3)
3) The value can increase to approx. 600 mW if the power available at the DSI-AD2 bus allows it.
MiVoice 5380 DSI-AD2 interface 1340
3)
MiVoice 5370, MiVoice 5380 with power supply unit DSI-AD2 interface 0
Expansion key module MiVoice M530 MiVoice 5370 300
Expansion key module MiVoice M530 MiVoice 5380 500
Expansion key module MiVoice M535 MiVoice 5370, MiVoice 5380 0
4)
4) An MiVoice M535 always requires a power supply unit
Dialog 4220 DSI-DASL interface 500
Dialog 4222 DSI-DASL interface 660
Dialog 4223 DSI-DASL interface 680
EKP expansion key module Dialog 4222, Dialog 4223 190
DECT radio unit without power supply unit SB-4+ DSI-AD2 interface 1700
5)
5) The value applies to radio units with hardware version "-2". The value for hardware version "-1" is 300 mW
lower.
DECT radio unit without power supply unit SB-8 2 DSI-AD2 interfaces 1550
6)
DECT radio unit with power supply unit SB-4+/SB-8 1 or 2 DSI-AD2 interfaces < 100
Office 10
2)
DSI-AD2 interface 900
Office 25
2)
DSI-AD2 interface 900
Office 35
2)
DSI-AD2 interface 630
7)
Office 45
2)
DSI-AD2 interface 1110
7)
Office 45pro power supply unit
2)
DSI-AD2 interface < 10
Expansion key module (EKP)
2)
Office 35 150
Expansion key module (EKP)
2)
Office 45 210
Alpha keyboard
2)
Office 35, Office 45 30

Table of Contents