12-26
Disassembly sequence
1 Snap ring
2 Valve
3 Spring
4 Body
Assembly sequence
Follow the disassembly sequence in re-
verse.
Service standards (Unit: mm)
Location Maintenance item Standard value Limit Remedy
– Regulator valve opening pressure
0.49 ± 0.03 MPa
{5.0 ± 0.3 kgf/cm
2
}
–Replace
3 Spring installed load (installed length 48.3)
78 ± 2 N
{8.0 ± 0.2 kgf}
–Replace
M
ITSUBISHI 6M70 REGULATOR VALVE