15
15-21
6. Inspection of Electrical Equipment
#566 Inspection of turbocharger magnetic valve
Perform the following tests on the turbocharger magnetic valve.
Replace the valve if found faulty.
(1) Valve activation test
Gradually increasing from 0 V, apply voltage to the turbocharger
magnetic valve between the following terminals.
Measure voltage when turbocharger magnetic valve is activated.
(Listen to the operating sound for ON/OFF of the magnet valve.)
(2) Continuity and air tight test
Test air pressure: 981 kPa {10 kgf/cm
2
}
#835 Inspection of turbine speed sensor and pulse converter
unit
Test the turbine speed sensor and pulse converter unit as con-
nected to the turbocharger.
Disconnect the turbine speed sensor and pulse converter unit
from the electronic control unit harness at connectors. Then,
prepare and fit the test harness in place.
The sensor does not respond to manual rotation of the turbo-
charger compressor wheel. To make the sensor responsive,
start the engine to be idling.
Measure the maximum level (high-pulse voltage) and minimum
level (low-pulse voltage) of voltage appearing between test con-
nector terminals 4 and 1.
If the measurement deviates the standard value, replace the tur-
bine speed sensor and pulse converter unit.
Terminals
4-pin connector
1-3 No. 1 magnetic valve
2-4 No. 2 magnetic valve
2-pin connector 1-2 No. 3 magnetic valve
Reference value
(minimum activation voltage)
18 V or less
Standard value
Low-pulse voltage 0 V
High-pulse voltage 5 V

Table of Contents