17
17-29
Removal sequence
CAUTION
• For information on the element replacement interval, refer to the element instruction manual. If the ele-
ment is used beyond its replacement interval, it may become clogged, causing the pressure inside the en-
gine to increase such that oil leakage occurs.
Installation sequence
Perform installation by following the removal sequence in reverse.
Tightening torque (Unit: N·m {kgf·m})
Mark Parts to be tightened Tightening torque Remarks
Clamp 4.0 {0.4} –
Bolt (PCV pipe mounting)
54 {5.5} –
Bolt (oil separator mounting)
Bolt (PCV valve mounting) 24 {2.4} –
1 PCV hose
2 PCV pipe
3 PCV hose
4 PCV hose
5 PCV pipe
6 O-ring
7 PCV hose
8 Oil hose
9 Oil separator
10 Oil hose
11 Cap
12 O-ring
13 Element
14 PCV body
*
a: Rocker cover
: Non-reusable parts
PCV: Positive crankcase ventilation