14-30
Removal: Flange
Removal: Impeller
Removal: Bearing unit
Remove the bearing unit using a press. Heating the water pump
case to approximately 80°C will facilitate the removal.
CAUTION
The ram load applied to remove the bearing unit should not
exceed 9800 N {1000 kgf}.
When the bearing unit is replaced, always replace the unit
seal.
Inspection procedure
Inspection: Interference between flange and bearing unit
If the measurement deviates from the standard value, replace
the defective part(s).
CAUTION
Even if the measurement complies with the standard value,
reassembly must not be carried out more than twice.
Inspection: Interference between impeller and bearing unit
If the measurement deviates from the standard value, replace
the defective part(s).
CAUTION
Even if the measurement complies with the standard value,
reassembly must not be carried out more than twice.