15-34
Removal sequence
CAUTION
• Do not remove the safty element except for replacement.
• Never clean the safty element.
Installation sequence
Follow the removal sequence in reverse.
Service standards
Tightening torque (Unit: N·m {kgf·m})
Location Maintenance item Standard value Limit Remedy
1 Dust indicator activating negative pressure
9.12 ± 0.69 kPa
{930 ± 70 mmH
2
O}
–Replace
Mark Parts to be tightened Tightening torque Remarks
Clamp 3.0 to 3.5 {0.3 to 0.35} –
1 Dust indicator
2 Air tube
3 Vacuator valve
4 Lower air duct
5 Duct joint hose
6 Air intake hose
7 Cover
8 Outer element
9 Safety element
10 Body
AIR CLEANER