Cleaning procedure
Cleaning: Element
Blow a jet of compressed air at a pressure not higher than 685
kPa {7 kgf/cm
2
} against the inside surfaces of the element.
CAUTION
For the frequency and timing of cleaning, refer to the rele-
vant instruction manual. More frequent cleaning than nec-
essary could damage the element or cause dust and foreign
matter to be sucked into the engine.
Do not strike the element or hit it against another object to
remove dust.
Do not blow compressed air against outside surfaces of the
element.
Inspection procedure
Inspection: Element
Shine some electric light inside the element.
Replace the element if thin spots or broken parts are evident in
the filter paper, or if the packing at the top of the element is dam-
aged.
Also replace the element if the dust on the element is damp with
oily smoke or soot, regardless of the replacement schedule.
Inspection: Operation of dust indicator under specified neg-
ative pressure
Apply negative pressure to the dust indicator, and take the read-
ing when the red signal appears in the dust indicator window.
Replace the dust indicator if found faulty.