14
14-35
Service standards (Unit: mm)
Tightening torque (Unit: N·m {kgf·m})
Lubricant and/or sealant
Inspection procedure
Inspection: Thermostat
Stir the water using a stirring rod to maintain an even water tem-
perature in the container, then conduct the tests indicated below.
If the measurement deviates from the standard value, replace
the thermostat.
(1) Valve opening temperature
Hold the thermostat with wire to keep it away from the heat
source.
Heat the water gradually to the valve opening temperature.
Maintain this temperature for five minutes and make sure that
the valve is completely open.
Make sure that the valve closes completely when the water tem-
perature drops below 65°C.
(2) Valve lift
Maintain the coolant temperature at the specified temperature
for five minutes to keep the valve fully open.
Measure the valve lift.
Location Maintenance item Standard value Limit Remedy
8 Thermostat
Valve opening
temperature
82 ± 2°C–
Replace
Valve lift/temperature 10 or more/95°C–
9 Thermostat
Valve opening
temperature
88 ± 2°C–
Valve lift/temperature 10 or more/100°C–
Mark Parts to be tightened Tightening torque Remarks
Water temperature sensor
For engine control
39 {40}
For thermometer
Overheat switch 27 to 41 {2.8 to 4.2}
Water joint 34 {3.5} Sealant
Eyebolt 25 {2.6}
Mark Points of application Specified lubricant and/or sealant Quantity
O-ring Engine oil As required
Winding around threaded portion of water joint Teflon tape 3.5 turns

Table of Contents