13
13-67
Service standards
Tightening torque (Unit: N·m {kgf·m})
Lubricant and/or sealant
Special tools (Unit: mm)
Removal procedure
Removal: Fuel suction pipe and fuel feed pipe
• Apply (width across flats: 24 mm) to the connector of the
supply pump as a stopper, and then loosen the eyebolt to re-
move the fuel suction pipe and fuel feed pipe.
CAUTION
• Do not use except for a stopper of the fuel suction pipe
and fuel feed pipe, otherwise the open end section may be
broken.
Location Maintenance item Standard value Limit Remedy
8 Overflow valve
0.23 ± 0.07 MPa
{2.3 ± 0.7 kgf/cm
2
}
–Replace
Mark Parts to be tightened Tightening torque Remarks
Bolt (supply pump mounting) 54 {5.5} –
Eyebolt (fuel suction pipe mounting)
25 to 29 {2.6 to 3.0} –
Eyebolt (fuel feed pipe mounting)
Eyebolt (oil pipe mounting) 21 {2.1} –
Overflow valve mounting 30 to 40 {3.1 to 4.1} –
Fuel pipe 29 to 35 {3.0 to 3.6} –
Bolt (supply pump mounting) 125 {12.7} –
Mark Points of application Specified lubricant and/or sealant Quantity
O-ring Engine oil As required
Mark Tool name and shape Part No. Application
Timing bolt
ME350296 Installation of supply pump
Open end spanner
ME355665
Removal and installation of fuel suc-
tion pipe and fuel feed pipe
A
φ10
AB
15 24
M
itsubishi 6M70 Engine Parts contact:
email: EngineParts@HeavyEquipmentRestorationParts.com
Phone: 269 673 1638