14
14-15
Removal sequence
Installation sequence
Follow the removal sequence in reverse.
Install each hose clamp to the angle indicated in the illustration so that sufficient clearance is assured between the
hose clamp and its surrounding parts.
Tightening torque (Unit: N·m {kgf·m})
Mark Parts to be tightened Tightening torque Remarks
Clamp 3.9 {0.4}
Eyebolt (water pipe mounting) 39 {4.0}
1 Air pipe
2 Water pipe
3 Water hose
4 Water hose
5 Eyebolt
6 Eyebolt
7 Water pipe
8 Water hose
9 Water pipe
10 Eyebolt
11 Eyebolt
12 Water pipe
13 Eyebolt
14 Eyebolt
15 Water pipe
16 Water hose
17 Water hose
18 Water hose
19 Water pipe
20 Water pipe
21 Water hose
*
a: Exhaust gas recirculation