14-20
Adjust the stopper bolt until the gap dimension shown in the il-
lustration is obtained on the attachment of .
CAUTION
Before using , be sure to set the gap to the specified di-
mension by adjusting the stopper bolt. Otherwise, damaged
will result.
Use to bend open tabs of retain tank in place.
After tabs are bent open, squeeze the handle
of
to straight-
en tabs as illustrated.
After straightening all tabs in the perimeter, hold the pipes con-
nected to the inlet/outlet, and remove tank.
If it is difficult to remove tank lightly hit with rubber hammer (or
plastic hammer) to remove.
CAUTION
Gently handle tanks, since they are made of a resin that can
break on impact.
Inspection procedure
Inspection: Tank surface where core is to be mounted
Check and clean the tank surface where the core is to be mount-
ed for cleanliness, damage, etc.
If any abnormality is found, replace the tank.
CAUTION
To prevent adhesion of foreign substances on mounting
surface, conduct work with bare hands.
RADIATOR AND FAN SHROUD