(2) Full automatic air conditioner
(2.1) Connection of LED for inspec-
tion
Move the starter switch to the LOCK
position.
Connect the LED for inspection to the
Multi-Use Tester connector.
CAUTION
Air conditioner electronic control
unit and control panel has a backup
power supply to keep diagnostic
check results in memory. If this
power supply is cut off, with battery
cables disconnected, for example,
stored data are erased.
Air conditioner electronic control
unit and control panel enters into
the mode of control during fault im-
mediately a fault occurs. In this
mode, control is effected to mini-
mize trouble arising from the fault.
(2.2) Reading and erasing diagnosis codes
To read a diagnosis code, observe how may times the LED for
inspection flashes and how long each illumination lasts.
The duration of illumination differs between the first and second
digits.
Second digit: 1.5 sec.
First digit: 0.5 sec.
A diagnosis code consists of the flashing of second digit and the
flashing of first digit in that order. If a diagnosis code has “0” in
the second digit, only the first digit will be displayed.
When two or more faults occur at a time, relevant diagnosis
codes are displayed repeatedly starting from the first Code.
To erase a diagnosis code from the memory after inspection,
disconnect negative (–) battery cable and leave it disconnected
for more than 30 seconds.