FX Series Programmable Controlers Applied Instructions 5
5-163
*3 The instruction drive timing is delayed by one opeation cycle to prevent simultaneous
driving of positioning instructions.
Moves to the absolute position
"500,000" using the absolute
positioning instruction.
(Y004 is ON.)
Reverse rotation positioning
completionflag
Positioning in the normal direction
is finished (self-reset).
Moves to the absolute position
"100" using the absolute
positioning instruction.
(Y004 is OFF.)
Positioning in the reverse
direction is finished (self-reset).
Normal rotation positioning
completionflag
M12SET
S12RST
S12
FNC159
DRVA
K500000 K100000 Y000 Y004
D
Absolute
position
specification
Output pulse
frequency
Pulse output
destination
No.
Rotation
direction signal
output
destination No.
M8029
M8147
Y000 being
output
M13SET
S13RST
S13
FNC159
DRVA
K100 K100000 Y000 Y004
D
M8029
M8147
Y000 being
output
Execution
completionflag
Execution
completionflag
Absolute
position
specification
Output pulse
frequency
Pulse output
destination
No.
Rotation
direction signal
output
destination No.
Positioning in normal rotation directionPositioning in reverse rotation direction
M53
M8000
RUN monit or
M53
*3
M53
M54
M8000
RUN monit or
M54
*3
M54