106
*1 Those are values when a hold trigger is detected at 10:35:40 on Tuesday, March 29th, 2011.
(8) Checking logging data
Logging data are stored in the following buffer memory areas.
1. Check the number of valid logging data in CH Number of logging data (Un\G1106 to Un\G1109).
Item Storage contents
Storage
example
*1
First two digits of the year/
Last two digits of the year
Stored in BCD code.
2011
H
Month/Day
329
H
Hour/Minute
1035
H
Second
40
H
Day of the week
One of the following value is stored for each day of the week in
BCD code.
2
H
• Sunday: 0 • Monday: 1
• Tuesday: 2 • Wednesday: 3
• Thursday: 4 • Friday: 5
• Saturday: 6
Channel
Collectable data Storing destination of logging data
Buffer memory name
Buffer
memory
address
Buffer memory name Buffer memory address
CH1
CH Digital output value
Un\G11
CH Logging data
Un\G5000 to Un\G14999
CH2 Un\G12 Un\G15000 to Un\G24999
CH3 Un\G13 Un\G25000 to Un\G34999
CH4 Un\G14 Un\G35000 to Un\G44999
CH1
CH Scaling value (digital operation
value)
Un\G54 Un\G5000 to Un\G14999
CH2 Un\G55 Un\G15000 to Un\G24999
CH3 Un\G56 Un\G25000 to Un\G34999
CH4 Un\G57 Un\G35000 to Un\G44999
When data is collected 10000 times or less
Valid data
Invalid data
(Data stored in this area is not reliable.)
1st data
2nd data
3rd data
4th data
5th data
6th data
9999th data
10000th data
When data is collected 10001 times or more
1st data
2nd data
3rd data
4th data
5th data
6th data
9999th data
10000th data
: 5
CH Number of
logging data
Valid data
CH Number of
logging data
: 10000